ECONOMIC PROTECTION MODULE.
 
 
 

ECONOMIC PROTECTION MODULE.

PROGRAMABLE AT USER END (FOR THE LOAD OF UP TO 2.0 Tr. SINGLE PHASE).

 

  • PROTECTS AGAINST HIGH VOLTAGE. USER CAN SET ANY WHERE IN THE RANGE OF 240VAC TO 260VAC. RE-SETS AUTOMATICALLY. (CUT- IN AT MINUS 5V).
  • PROTECTS AGAINST LOW VOLTAGE. USER CAN SET ANY WHERE IN THE RANGE OF 200VAC TO 180VAC. RE-SETS AUTOMATICALLY. (CUT- IN AT +10 V).
  • PROTECTS AGAINST OVER CURRENT / OVER LOAD / SHORT CIRCUIT. USER CAN SET ANY WHERE IN THE RANGE OF 01 AMPERE TO 20 AMPERES, AS PER LOAD CURRENT OF THE MACHINE. RE-SETS MANUALLY BY POWER CUTOFF, THEN SWITCH ON AGAIN.
  • POWER“ON” DELAY. USER CAN SET ANY WHERE IN THE RANGE OF 10 SECONDS TO 180 SECONDS, ON THE STEP OF 5 SECONDS, WITH DOWN COUNTER.
  • IN THE ROUTINE MODE, THIS DEVICE DISPLAYS INCOMMING VOLTAGE & RUNNING CURRENT, ON 3 DIGITS SEVEN SEGMENT DISPLAY. BOTH READINGS SCROLLS AT 10 SECONDS INTERVEL.
  • ERROR CODES:-

“OS” (over supply) FOR HIGH VOLTAGE.

“US” (under supply) FOR LOW VOLTAGE.

“OC” FOR OVER CURRENT / OVER LOAD / SHORT CIRCUIT.

  • USER CAN “LOCK” & “UN-LOCK” THIS DEVICE, AFTER PROGRAMING or BEFORE PROGRAMING. KEEP PRESSED INCREASE SWITCH FOR 5 SECONDS TO LOCK or UNLOCK. DISPLAY WILL SHOW “LO” WHEN LOCKED & “UL” WHEN UNLOCKED.
  • USER CAN HOLD & RELEASE “VOLTAGE” or “CURRENT” READING IN ROUTINE MODE FOR LONG TIME MONITORING. KEEP PRESSED DECREASE SWITCH FOR 5 SECONDS TO HOLD & RELEASE.
  • DURING ERROR CONDITIONS, THIS DEVICE ALLOWES TO ENTER INTO PROGRAMME MODE, FOR REPROGRAMMING.
  • PROTECTS AGAINST WEAK NEUTRAL TOO.

11-       HEAT RESISTANT TAFLON WIRES ARE USED IN LOAD LINES.

12-       MATELLIC POWDER COATED WALL MOUNTED CABINET IS USED.

13-       USER FRIENDLY OPERATION & INSTALLATION.

PROGRAMING PROCEDURE

  • PRESS “MENU” SWITCH. CONTROLLER WILL ASK FOR THE SETTING OF “OS”. FILL UP THE REQUIRED VALUE BY THE HELP OF “INCREASE” & “DECREASE” SWITCH. NOW SAVE YOUR SETTING BY PRESSING “ENTER” SWITCH.
  • PRESS “MENU” SWITCH AGAIN. CONTROLLER WILL ASK FOR THE SETTING OF “US”. FILL UP THE REQUIRED VALUE BY THE HELP OF “INCREASE” & “DECREASE” SWITCH. NOW SAVE YOUR SETTING BY PRESSING “ENTER” SWITCH.
  • PRESS “MENU” SWITCH AGAIN. CONTROLLER WILL ASK FOR THE SETTING OF “OC”. FILL UP THE REQUIRED VALUE BY THE HELP OF “INCREASE” & “DECREASE” SWITCH. NOW SAVE YOUR SETTING BY PRESSING “ENTER” SWITCH.
  • PRESS “MENU” SWITCH AGAIN. CONTROLLER WILL ASK FOR THE SETTING OF “Sd” (POWER ON DELAY). FILL UP THE REQUIRED VALUE BY THE HELP OF “INCREASE” & “DECREASE” SWITCH. NOW SAVE YOUR SETTING BY PRESSING “ENTER” SWITCH.
  • NOW PRESS “MENU” SWITCH ONCE AGAIN TO EXIT FROM PROGRAMING MODE.
 
 