REAL TIME & CALANDER BASED PROGRAMABLE TIMER.
 
 
 

REAL TIME & CALANDER BASED PROGRAMABLE TIMER (MAT-14).

 

 

 

MAT-14 IS A REAL CLOCK & CALENDER BASED, MICRO-CONTROLLED DEVICE.

IT HAVE TWO FIELD SELECTABLE MODES & TWO OUT PUT (RL-1 & RL-2).

♦ AIRCON MODE.

♦ HORDING MODE.

 AS USER POWER-UP THE CONTROLLER, FOLLOWING MASSAGES APPEAR ON THE 02 LINES LCD SCREEN (ONCE AT EVERY POWER-UP), FOR FIVE SECONDS EACH, 1st. massage IN

FIRST LINE :CARE TAKE DEVICE & IN SECOND LINE : PRESENTS,  2nd. massage  IN FIRST LINE : INTELLIGENT & IN SECOND LINE : MULTI APP. TIMER.

AFTER THE ABOVE MASSAGE, LCD SCREEN SCROLLS AT 5 SECONDS INTERVEL REGULERLY, TO DISPLAY THE ROUTINE OF THE RUNNING MODE. FIRST, IT DISPLAYS THE REAL CALANDER WITH THE REAL TIME, THEN THE SELECTED MODE WITH IT’S NEXT SCHEDULE FOR BOTH OUT PUT, for example, USER SELECTS AIRCON MODE,

THU – 01/01/2015                   AIRCON MODE                                AIRCON MODE

12:06 PM                                 RL-1 OFF – 12:45 PM                        RL-2 ON – 12:15PM

NOTES:-

1- THE OUT PUT WILL SWITCH-ON or SWITCH-OFF AS PER PROGRAMMED SCHEDULE AND LOGICS.

2- IN AIRCON MODE, RL-1 WORKS FROM ON CYCLE TO OFF CYCLE & RL-2 WORKS FROM OFF CYCLE TO ON CYCLE.

3- GREEN COLOUR LED IS USED FOR OFF AND RED COLOUR LED FOR ON INDICATION.

4- BY-PASS SWITCHES FOR BOTH OUT PUT IS AVAILABLE, IN ORDER TO BY-PASS MAT-14, IN CASE OF ANY EMERGENGY or FAILURE.

5- KEYS

a- MENU KEY, KEEP PRESS FOR 3 SECONDS, TO ENTER INTO PROGRAMMING MODE.

b- UP KEY, TO INCREASE VALUES, USER WOULD LIKE TO SET.

c- DOWN KEY, TO INCREASE VALUES, USER WOULD LIKE TO SET.

d- ENTER KEY, TO SAVE ENTEREDVALUES.

e- LEFT KEY, TO GO BACK WARD IN PROGRAM.

f- RIGHT KEY, TO GO FORWARD IN PROGRAM, or TO SKIP PARAMETERS.

 KEEP PRESS TILL 3 SECONDS, UP KEY TO LOCK THE KEY BOARD, AFTER PROGRAMING.

KEEP PRESS TILL 3 SECONDS, DOWN KEY TO UN-LOCK THE KEY BOARD.

THERE IS SCREEN SAVER FOR THE LCD SCREEN. IF THERE IS NO ACTIVITY ON SCREEN FROM USER END, IT WILL DIM AFTER 60 SECONDS.

SCREEN WILL LIGHT-UP BY DOWN KEY ONLY, IF KEY BOARD IS LOCKED.

SCREEN WILL LIGHT-UP BY UP, DOWN, ENTER, LEFT & RIGHT KEYS, WHEN KEY BOARD IS UN-LOCKED.

 IF USER, GOES INTO PROGRAM MODE, AND DOES NOT DO ANY ACTIVITY ON KEY BOARD, THE CONTROLLER COME OUT FROM PROGRAM AUTOMATICALLY AFTER 20 SECONDS.

  PROGRAMMING PROCEDURE AND FEATURES

  • KEEP PRESSED MENU KEY TILL 3 SECONDS, TO ENTER INTO PROGRAMING MODE,
  • SET CALANDER :- YEAR / MONTH / DATE / DAY., WITH THE HELP OF UP & DOWN KEYS. IF ALREADY PROGRAMMED, PRESS ENTER or RIGHT KEY, TO IF CHANGS SOME VALUE, PRESS ENTER KEY TO SAVE.
  • SET CLOCK :- ( IN 12 HOURS FORMATE ) HOURS / MINUTES / AM or PM.
  • SET MODE :- AIRCON MODE / HORDING MODE.
  • SELECT DEFAULT SETTING or PERSONEL SETTING IN AIRCON MODE.
  • HORDING MODE IS ONLY WITH DEFAULT SETTING.

AS MODE IS SELECTED, CONTROLLER ASK FOR THE SETTINGS AS UNDER,

 IN AIRCON MODE, CONTROLLER ASK FIRST FOR DEFAULT SETTING & PERSONAL SETTING. IF USER SELECT THE DEFAULT SETTING, CONTROLLER EXIT FROM PROGRAMING MODE. IF USER SELECT PERSONAL SETTING, THEN CONTROLLER ASK FOR SETTING.

DEFAULT SETTING.

DEFAULT POWER ON TIME IS 09 : 00 AM.

DEFAULT POWER OFF TIME IS 06 : 00 PM.

DEFAULT WEEKLY OFF IS SUNDAY.

DEFAULT ON CYCLE DURATION IS 45 MINUTES.

DEFAULT OFF CYCLE DURATION IS 15 MINUTES.

PERSONAL SETTING.

 

  • POWER ON TIME (SET AS PER ACTUAL TIME, BETWEEN 00:01AM TO 11:59PM).
  • POWER OFF TIME (SET AS PER ACTUAL TIME, BETWEEN 00:01AM TO 11:59PM).
  • ON CYCLE DURATION (45 TO 90 MINUTES).
  • OFF CYCLE DURATION (10 TO 30 MINUTES).
  • WEEKLY OFF :- SUNDAY ONLY / SAT.& SUN. (OFF-1 , OFF-2)

 

AS USER WILL PRESS ENTER KEY AFTER LAST ENTRY, CONTROLLER WILL EXIT FROM PROGRAMING MODE. NOW, LCD WILL DISPLAY, IN SCROLLING WAY, AS PER ABOVE EXAMPLE. ABOVE SETTING WILL BE APPLICABLE FOR LIFE TIME, UNTILL NOT CHANGE.

 

IF USER FILL “00” IN POWER ON TIME, THE SETTINGS OF ON CYCLE AND OFF CYCLE WILL BE APPLICABLE FOR 24 Hrs. THERE WILL BE NEITHER POWER ON TIME NOR POWER OFF TIME.

 

IN HORDING MODE, CONTROLLER WORKS ON DEFAULT SETTING.

ON TIME IS VERY CLOSE TO ACTUAL SUN SET TIME. OFF TIME IS 12:00 MID NIGHT, IN ALL WEATHERS.

 

                                    ON TIME                                                                   ON TIME      

1 JAN TO 15 JAN      5:35PM                        16 JAN TO 31 JAN                5:45PM

1 FEB TO 15 FEB       6:00PM                        16 FEB TO 28 FEB                 6:10PM

1 MAR TO 15 MAR   6:20PM                        16 MAR TO 31 MAR             6:30PM

1 APR TO 15 APR      6:35PM                        16 APR TO 30 APR                5:45PM

1 MAY TO 15 MAY   6:55PM                        16 MAY TO 31 MAY 7:00PM

1 JUN TO 15 JUN      7:15PM                        16 JUN TO 30 JUN                7:20PM

1 JUL TO 15 JUL        7:20PM                        16 JUL TO 31 JUL                  7:20PM

1 AUG TO 15 AUG    7:15PM                        16 AUG TO 31 AUG              7:00PM

1 SEP TO 15 SEP       6:45PM                        16 SEP TO 30 SEP                 6:25PM

1 OCT TO 15 OCT     6:10PM                        16 OCT TO 31 OCT               5:50PM

1 NOV TO 15 NOV   5:35PM                        16 NOV TO 30 NOV             5:30PM

1 DEC TO 15 DEC     5:25PM                        16 DEC TO 31 DEC               5:25PM

 

AS USER WILL PRESS ENTER KEY ON HORDING MODE, CONTROLLER WILL EXIT FROM PROGRAMING MODE. NOW, LCD WILL DISPLAY, IN SCROLLING WAY, AS PER ABOVE EXAMPLE.

 

IF POWER FAILS DURING ANY RUNNIG SCHEDULE, AND POWER REGAINS, STATUS OF OUT

PUT REMAINS SAME AS PROGRAMMED.

For example, ON TIME = 09:00 AM, OFF TIME = 01:00 PM, AND POWER FAILS AT 10:30 AM, AND REGAINS AT 11:45PM, THE OUT PUT WILL BE “ON” FOR UP TO 01:00PM, BECAUSE, OFF TIME IS 01:00PM.

 

WIRED WITH HEAT RESISTANT TAFLON COATED WIRES, IN LOAD LINE.

 

BUILT WITH WEATHER PROOF ENCLOSER, FOR OUT DOOR USE TOO.

 

USING HIGH QUALITY COMPONENTS, DUE TO FLUCTUATION IN POWER SUPPLY.

 

 
 
WhatsApp Click To Chat WatsApp With Us